{"id":995,"date":"2016-11-08T10:58:48","date_gmt":"2016-11-08T09:58:48","guid":{"rendered":"https:\/\/www.syntech-hag.it\/application\/procedura\/"},"modified":"2020-03-24T18:43:06","modified_gmt":"2020-03-24T17:43:06","slug":"procedure","status":"publish","type":"page","link":"https:\/\/www.syntech-hag.com\/application\/procedure\/","title":{"rendered":"Procedure"},"content":{"rendered":"<p>[vc_row row_type=&#8221;row_full_center_content&#8221; margin_top=&#8221;0&#8243; padding_top=&#8221;0&#8243;][vc_column][vc_column_text]<strong>Water infiltrations<\/strong>, deriving either from accidental events, from possible imprecision, from significant changes occurring on the ground water and so on, can involve the most diverse materials such as concrete, solid masonry of different composition, rocky elements for conferring, etc. The appearance of infiltrations and, above all, their continuation can be a source of considerable economic damage: the unavailability of the affected areas, damage to operating machines, cars, furnishings and so on.<\/p>\n<p><strong>SYNTECH HAG water-reactive polyurethane resins, which catalyze in a few seconds due to their self-expanding properties, hermetically seal the cracks, forever!<\/strong><\/p>\n<p>Usually the intervention is carried out, except in special cases, without any preparation of the crack and the resins are at perfect ease even in the presence of pressurized water, even very high.\u00a0It is possible to intervene from both inside and outside the building, without any demolition or excavations.\u00a0Given the extreme rapidity of the hydro-expansive reaction of SYNTECH HAG resins, it is possible to immediately verify the effectiveness of the intervention.[\/vc_column_text][\/vc_column][\/vc_row][vc_row row_type=&#8221;row_full_center_content&#8221; margin_top=&#8221;0&#8243; margin_bottom=&#8221;0&#8243; padding_top=&#8221;0&#8243; padding_bottom=&#8221;0&#8243;][vc_column css=&#8221;.vc_custom_1452593439007{padding-top: 0px !important;padding-bottom: 20px !important;}&#8221;][vc_raw_html]JTNDZGl2JTIwY2xhc3MlM0QlMjJhemlvbmlUaXRsZSUyMiUzRSUwQSUzQ3NwYW4lM0UxJTNDJTJGc3BhbiUzRSUwQSUzQ3AlM0VDTEVBTklORyUyMEFORCUyMFNFQUxJTkclMjBPRiUyMElOSlVSSUVTJTIwQU5EJTIwQURKQUNFTlQlMjBTVVJGQUNFUyUzQyUyRnAlM0UlMEElM0MlMkZkaXYlM0U=[\/vc_raw_html][vc_row_inner][vc_column_inner width=&#8221;1\/4&#8243;][vc_single_image image=&#8221;124&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; el_class=&#8221;proceduraDisegni&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;3\/4&#8243;][vc_column_text]It is always advisable to clean the surfaces affected by the crack, the crawl space or the joint to be waterproofed, especially where the surfaces themselves are invaded by mosses, limestone and generally soiled.<br \/>\nCorrect cleaning with a pressure washer, with a steel brush or hard plastic bristles or with a normal cloth, depending on the case, allows, among other things, to highlight the position and course of the lesion and to draw the consequent results. intervention evaluations. The need to pre-seal the crack (for example, with instant-hold products like OSMOCEM QUICK) depends on the width of the crack itself and on the presence of copious water leaks.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row row_type=&#8221;row_full_center_content&#8221; margin_top=&#8221;20&#8243; margin_bottom=&#8221;0&#8243; padding_top=&#8221;0&#8243; padding_bottom=&#8221;0&#8243;][vc_column css=&#8221;.vc_custom_1452593439007{padding-top: 0px !important;padding-bottom: 20px !important;}&#8221;][vc_raw_html]JTNDZGl2JTIwY2xhc3MlM0QlMjJhemlvbmlUaXRsZSUyMiUzRSUwQSUzQ3NwYW4lM0UyJTNDJTJGc3BhbiUzRSUwQSUzQ3AlM0VFU0VDVVRJT04lMjBPRiUyMFRIRSUyMFBFUkZPUkFUSU9OUyUzQyUyRnAlM0UlMEElM0MlMkZkaXYlM0U=[\/vc_raw_html][vc_row_inner][vc_column_inner width=&#8221;1\/4&#8243;][vc_single_image image=&#8221;125&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; el_class=&#8221;proceduraDisegni&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;3\/4&#8243;][vc_column_text]The injection holes can be drilled with different diameters, depths and angles.<br \/>\nIn principle, a standard hole must have a diameter between 8 and 12 mm and must be drilled at an angle of about 45\u00b0, on either side of the crack or joint (Quincunx).<br \/>\nThe distance between each injection hole and the next depends on the width of the crack: generally it varies between 15 and 90 cm, while the distance of the holes, with respect to the slot or the joint, is generally equal to 1\/2 of the thickness of the structure and always variable in relation to the size and importance of the structure itself (dams, large retaining walls, rocks, etc.).<br \/>\nThe holes must be conveniently clean from dust with an air compressor or manual air extractor.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row row_type=&#8221;row_full_center_content&#8221; margin_top=&#8221;20&#8243; margin_bottom=&#8221;0&#8243; padding_top=&#8221;0&#8243; padding_bottom=&#8221;0&#8243;][vc_column css=&#8221;.vc_custom_1452593439007{padding-top: 0px !important;padding-bottom: 20px !important;}&#8221;][vc_raw_html]JTNDZGl2JTIwY2xhc3MlM0QlMjJhemlvbmlUaXRsZSUyMiUzRSUwQSUzQ3NwYW4lM0UzJTNDJTJGc3BhbiUzRSUwQSUzQ3AlM0VJTlNUQUxMQVRJT04lMjBPRiUyMElOSkVDVE9SUyUzQyUyRnAlM0UlMEElM0MlMkZkaXYlM0U=[\/vc_raw_html][vc_row_inner][vc_column_inner width=&#8221;1\/4&#8243;][vc_single_image image=&#8221;126&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; el_class=&#8221;proceduraDisegni&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;3\/4&#8243;][vc_column_text]Widen the holes drilled of few centimeters, using the drill with a 12 or 13 mm diameter tip.<br \/>\nInstall the <strong>SYNTECH HAG INIETTORE 120<\/strong> or <strong>170<\/strong> flat head screw injectors (based on site requirements), equipped with a non-return seal valve, by hand or by simple percussion with a hammer and tighten them with a 10 or flat wrench, turning clockwise until a complete &#8220;expansion&#8221; of its rubber part and fixing to the support.<br \/>\nIn order to remove from the holes the dust and debris produced by the action of the drill and to ensure the necessary presence of humidity or water, if missing, provide a preliminary injection of water, providing for the subsequent cleaning of the pumping system, with diluent Nitro type, in order to avoid unpleasant clogging of the pumping circuit.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row row_type=&#8221;row_full_center_content&#8221; margin_top=&#8221;20&#8243; margin_bottom=&#8221;0&#8243; padding_top=&#8221;0&#8243; padding_bottom=&#8221;0&#8243;][vc_column css=&#8221;.vc_custom_1452593439007{padding-top: 0px !important;padding-bottom: 20px !important;}&#8221;][vc_raw_html]JTNDZGl2JTIwY2xhc3MlM0QlMjJhemlvbmlUaXRsZSUyMiUzRSUwQSUzQ3NwYW4lM0U0JTNDJTJGc3BhbiUzRSUwQSUzQ3AlM0VNSVglMjBQUkVQQVJBVElPTiUzQyUyRnAlM0UlMEElM0MlMkZkaXYlM0U=[\/vc_raw_html][vc_row_inner][vc_column_inner width=&#8221;1\/4&#8243;][vc_single_image image=&#8221;127&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; el_class=&#8221;proceduraDisegni&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;3\/4&#8243;][vc_column_text]<\/p>\n<p style=\"margin: 0cm; margin-bottom: .0001pt; background: white;\">Mix thoroughly in a bucket, with a suitable wooden or iron rod, the hydrophilic resin component, <strong>SYNTECH HAG FLEX<\/strong> or <strong>ECO<\/strong> hydro-expansive (based on site requirements) with the preset amount of expansion activator \/ accelerator (component B ). The recommended dosage of 0.1 kg of component B each 1 kg of component A can be varied (increase in component B in the mixture) in relation to the intensity and severity of the infiltration.<br \/>\nThis possible increase allows to regulate the reaction speed of the hydro-expansive resin with water.<br \/>\nThe amount of resin and activator to be used, from time to time, is the one that will surely be able to inject depending on the personnel employed and the difficulty of the site, in any case never exceeding 2 &#8211; 3 kg.<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row row_type=&#8221;row_full_center_content&#8221; margin_top=&#8221;20&#8243; margin_bottom=&#8221;0&#8243; padding_top=&#8221;0&#8243; padding_bottom=&#8221;0&#8243;][vc_column css=&#8221;.vc_custom_1452593439007{padding-top: 0px !important;padding-bottom: 20px !important;}&#8221;][vc_raw_html]JTNDZGl2JTIwY2xhc3MlM0QlMjJhemlvbmlUaXRsZSUyMiUzRSUwQSUzQ3NwYW4lM0U1JTNDJTJGc3BhbiUzRSUwQSUzQ3AlM0VGSVhJTkclMjBUSEUlMjBJTkpFQ1RPUiUyMFdJVEglMjBUSEUlMjBQVU1QJTNDJTJGcCUzRSUwQSUzQyUyRmRpdiUzRQ==[\/vc_raw_html][vc_row_inner css=&#8221;.vc_custom_1476031386544{margin-bottom: 20px !important;}&#8221;][vc_column_inner width=&#8221;1\/4&#8243;][vc_single_image image=&#8221;128&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; el_class=&#8221;proceduraDisegni&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;3\/4&#8243;][vc_column_text]Insert the pump delivery pipe through the specific <strong>SYNTECH HAG CONNETTORE<\/strong>\u00a0interlocking accessory, ensuring the perfect &#8220;tightening&#8221; of the hose-injector connection before proceeding with the injections.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row row_type=&#8221;row_full_center_content&#8221; margin_top=&#8221;20&#8243; margin_bottom=&#8221;0&#8243; padding_top=&#8221;0&#8243; padding_bottom=&#8221;0&#8243;][vc_column css=&#8221;.vc_custom_1452593439007{padding-top: 0px !important;padding-bottom: 20px !important;}&#8221;][vc_raw_html]JTNDZGl2JTIwY2xhc3MlM0QlMjJhemlvbmlUaXRsZSUyMiUzRSUwQSUzQ3NwYW4lM0U2JTNDJTJGc3BhbiUzRSUwQSUzQ3AlM0VJTkpFQ1RJT04lMjBPRiUyMEhZRFJPLUVYUEFOU0lWRSUyMFJFU0lOUyUzQyUyRnAlM0UlMEElM0MlMkZkaXYlM0U=[\/vc_raw_html][vc_row_inner][vc_column_inner width=&#8221;1\/4&#8243;][vc_single_image image=&#8221;129&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; el_class=&#8221;proceduraDisegni&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;3\/4&#8243;][vc_column_text]After preparing the resinous mixture and appropriately inserting the delivery pipe of the pump, injections have to be made in the following ways:<\/p>\n<ol>\n<li>In the case of cracks or vertical joints, injection will start from the first injector installed from the bottom upwards: during the injection it will be possible to notice that the resin will remove the water present in the slot. Continue the injection until the resin arrives, coming out, near the next injector or until the pumping effort becomes excessive.<\/li>\n<li>Eliminate the air introduced during pumping using the valve of air discharge and, only after ensuring that the air has completely come out, disconnect the pump connection pipe from the injector, and repeat the operation with the next one. The injection pressure is variable depending on the depth of the crack, the structural thickness and the porosity or compactness of the material of the structure. The amount of hydro-expansive resin required will vary, in turn, depending on the characteristics mentioned (depth, thickness, etc.). In standard situations (small cracks, connections between walls and slabs, structural joints, etc.) the consumption of resin can be around 1 kg \/ linear meter.<\/li>\n<\/ol>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row row_type=&#8221;row_full_center_content&#8221; margin_top=&#8221;20&#8243; margin_bottom=&#8221;0&#8243; padding_top=&#8221;0&#8243; padding_bottom=&#8221;0&#8243;][vc_column css=&#8221;.vc_custom_1452593439007{padding-top: 0px !important;padding-bottom: 20px !important;}&#8221;][vc_raw_html]JTNDZGl2JTIwY2xhc3MlM0QlMjJhemlvbmlUaXRsZSUyMiUzRSUwQSUzQ3NwYW4lM0U3JTNDJTJGc3BhbiUzRSUwQSUzQ3AlM0VSRU1PVkFMJTIwT0YlMjBUSEUlMjBSRVNJTiUyMExFQUtBR0UlMjBBTkQlMjBSRU1PVkFMJTIwT0YlMjBUSEUlMjBJTkpFQ1RPUlMlM0MlMkZwJTNFJTBBJTNDJTJGZGl2JTNF[\/vc_raw_html][vc_row_inner][vc_column_inner width=&#8221;1\/4&#8243;][vc_single_image image=&#8221;130&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; el_class=&#8221;proceduraDisegni&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;3\/4&#8243;][vc_column_text]<\/p>\n<p style=\"margin: 0cm; margin-bottom: .0001pt; background: white;\">The hydro-expansive resin, escaping from the cracks, joints and crawl spaces at the end of the injections, can develop, especially on dry supports, a remarkable adherence to the surfaces.<br \/>\nPost-injection cleaning can sometimes require the use of a metal scraper to remove residues.<br \/>\nThe injectors installed can be removed from their seats by cutting with a flexible disk at the base of the injector and then filling the hole, possibly resulting, with REPAR TIX thixotropic cement mortar.<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row row_type=&#8221;row_full_center_content&#8221; margin_top=&#8221;20&#8243; margin_bottom=&#8221;0&#8243; padding_top=&#8221;0&#8243;][vc_column css=&#8221;.vc_custom_1452593439007{padding-top: 0px !important;padding-bottom: 20px !important;}&#8221;][vc_raw_html]JTNDZGl2JTIwY2xhc3MlM0QlMjJhemlvbmlUaXRsZSUyMiUzRSUwQSUzQ3NwYW4lM0U4JTNDJTJGc3BhbiUzRSUwQSUzQ3AlM0VDTEVBTklORyUyMFRIRSUyMFBVTVAlMjBBTkQlMjBBQ0NFU1NPUklFUyUzQyUyRnAlM0UlMEElM0MlMkZkaXYlM0U=[\/vc_raw_html][vc_row_inner][vc_column_inner width=&#8221;1\/4&#8243;][vc_single_image image=&#8221;131&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; el_class=&#8221;proceduraDisegni&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;3\/4&#8243;][vc_column_text]Immediately after the injections, it is necessary to clean the equipment that has been in contact with the hydro-expansive resin, proceeding as follows:<\/p>\n<ol>\n<li>draw with the nitro diluent tube and circulate it into the pump until it comes out of the delivery pipe. This action must be repeated several times until every residue of fluid has completely exited from the pump;\u00a0then make it spin when dry and then, if necessary, repeat the operation.<\/li>\n<li>Before placing the cleaned pump, place the specific\u00a0<strong>SYNTECH HAG CLEANER <\/strong>lubricant cleaner in the circuits, so that the pump remains properly lubricated.<\/li>\n<\/ol>\n<p>Clean the accessories used for the work with the same cleaning agents.<br \/>\nNB: The resulting materials must be disposed of in compliance with the applicable regulations and standards.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row row_type=&#8221;row_full_center_content&#8221; margin_top=&#8221;0&#8243; padding_top=&#8221;0&#8243;][vc_column][vc_column_text]Water infiltrations, deriving either from accidental events, from possible imprecision, from significant changes occurring on the ground water &#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":992,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v22.2 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Procedure - Syntech Hag<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.syntech-hag.com\/application\/procedure\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Procedure - Syntech Hag\" \/>\n<meta property=\"og:description\" content=\"[vc_row row_type=&#8221;row_full_center_content&#8221; margin_top=&#8221;0&#8243; padding_top=&#8221;0&#8243;][vc_column][vc_column_text]Water infiltrations, deriving either from accidental events, from possible imprecision, from significant changes occurring on the ground water ...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.syntech-hag.com\/application\/procedure\/\" \/>\n<meta property=\"og:site_name\" content=\"Syntech Hag\" \/>\n<meta property=\"article:modified_time\" content=\"2020-03-24T17:43:06+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"9 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.syntech-hag.com\/application\/procedure\/\",\"url\":\"https:\/\/www.syntech-hag.com\/application\/procedure\/\",\"name\":\"Procedure - Syntech Hag\",\"isPartOf\":{\"@id\":\"https:\/\/www.syntech-hag.it\/#website\"},\"datePublished\":\"2016-11-08T09:58:48+00:00\",\"dateModified\":\"2020-03-24T17:43:06+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.syntech-hag.com\/application\/procedure\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.syntech-hag.com\/application\/procedure\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.syntech-hag.com\/application\/procedure\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.syntech-hag.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Application\",\"item\":\"https:\/\/www.syntech-hag.com\/application\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Procedure\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.syntech-hag.it\/#website\",\"url\":\"https:\/\/www.syntech-hag.it\/\",\"name\":\"Syntech Hag\",\"description\":\"Arresto immediato infiltrazioni d&#039;acqua\",\"publisher\":{\"@id\":\"https:\/\/www.syntech-hag.it\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.syntech-hag.it\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.syntech-hag.it\/#organization\",\"name\":\"Azichem srl\",\"url\":\"https:\/\/www.syntech-hag.it\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.syntech-hag.it\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.syntech-hag.it\/file\/2016\/11\/azichem-logo.png\",\"contentUrl\":\"https:\/\/www.syntech-hag.it\/file\/2016\/11\/azichem-logo.png\",\"width\":344,\"height\":90,\"caption\":\"Azichem srl\"},\"image\":{\"@id\":\"https:\/\/www.syntech-hag.it\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Procedure - Syntech Hag","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.syntech-hag.com\/application\/procedure\/","og_locale":"en_US","og_type":"article","og_title":"Procedure - Syntech Hag","og_description":"[vc_row row_type=&#8221;row_full_center_content&#8221; margin_top=&#8221;0&#8243; padding_top=&#8221;0&#8243;][vc_column][vc_column_text]Water infiltrations, deriving either from accidental events, from possible imprecision, from significant changes occurring on the ground water ...","og_url":"https:\/\/www.syntech-hag.com\/application\/procedure\/","og_site_name":"Syntech Hag","article_modified_time":"2020-03-24T17:43:06+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"9 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.syntech-hag.com\/application\/procedure\/","url":"https:\/\/www.syntech-hag.com\/application\/procedure\/","name":"Procedure - Syntech Hag","isPartOf":{"@id":"https:\/\/www.syntech-hag.it\/#website"},"datePublished":"2016-11-08T09:58:48+00:00","dateModified":"2020-03-24T17:43:06+00:00","breadcrumb":{"@id":"https:\/\/www.syntech-hag.com\/application\/procedure\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.syntech-hag.com\/application\/procedure\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.syntech-hag.com\/application\/procedure\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.syntech-hag.com\/"},{"@type":"ListItem","position":2,"name":"Application","item":"https:\/\/www.syntech-hag.com\/application\/"},{"@type":"ListItem","position":3,"name":"Procedure"}]},{"@type":"WebSite","@id":"https:\/\/www.syntech-hag.it\/#website","url":"https:\/\/www.syntech-hag.it\/","name":"Syntech Hag","description":"Arresto immediato infiltrazioni d&#039;acqua","publisher":{"@id":"https:\/\/www.syntech-hag.it\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.syntech-hag.it\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.syntech-hag.it\/#organization","name":"Azichem srl","url":"https:\/\/www.syntech-hag.it\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.syntech-hag.it\/#\/schema\/logo\/image\/","url":"https:\/\/www.syntech-hag.it\/file\/2016\/11\/azichem-logo.png","contentUrl":"https:\/\/www.syntech-hag.it\/file\/2016\/11\/azichem-logo.png","width":344,"height":90,"caption":"Azichem srl"},"image":{"@id":"https:\/\/www.syntech-hag.it\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.syntech-hag.com\/rest\/wp\/v2\/pages\/995"}],"collection":[{"href":"https:\/\/www.syntech-hag.com\/rest\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syntech-hag.com\/rest\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syntech-hag.com\/rest\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syntech-hag.com\/rest\/wp\/v2\/comments?post=995"}],"version-history":[{"count":4,"href":"https:\/\/www.syntech-hag.com\/rest\/wp\/v2\/pages\/995\/revisions"}],"predecessor-version":[{"id":1149,"href":"https:\/\/www.syntech-hag.com\/rest\/wp\/v2\/pages\/995\/revisions\/1149"}],"up":[{"embeddable":true,"href":"https:\/\/www.syntech-hag.com\/rest\/wp\/v2\/pages\/992"}],"wp:attachment":[{"href":"https:\/\/www.syntech-hag.com\/rest\/wp\/v2\/media?parent=995"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}